PARACHUTE SYSTEMS

This is a system which automatically operates if the car begins to go down due to machine gear doffing or breakage of carrying steel ropes and it locks the car mechanically so that it is hung to the sliding rails. The parachute system also cuts off the power supply of the systems and makes the elevator electrically secure.

LOCK SECURITY CIRCUITS

These electro-mechanical systems prevent the movement of the car while the floor and/or car doors are open and also the opening of the floor doors while the car is not at the floor.

LIMIT SWITCHES

These mechanisms are designed to cut off the power supply on the systems if the car continues to travel uncontrollably without stopping on the ground and the upper floors. The limit switches determine the shaft limits electrically.

BUMPERS

These are the components that absorb the power of impact caused by the fall of the car on the shaft base.

CAR SECURITY SYSTEM

Automatic car security doors 

:

Are designed to cut the contact of the passengers in the car with the floor doors and the shaft in case of an accident of being pinched between the car and shaft surface during travel..

Photocells

:

Prevent an accident of being pinched sensing an object in the doorway during the closing of the automatic doors and stopping the closing of the door and opening it again.
Photocells may be single-eye providing threshold protection at the knee level, double-eye providing threshold protection at the knee and hip level or even higher providing threshold protection across the door height. There are also thermal photocells which are sensitive only towards human body heat and not to non-living objects.

Pinching contact

:

Is a mechanism causing the door to open backward, which is activated by drive of squeeze pressure arising on the automatic door panel. It is adjustable at a rate not detrimental to human body if there is an object out of the area sensed by the photocell or if the door is shut onto and has pinched the object on the threshold due to a failure in the photocell.

Stop circuit

:

Enables the passengers in the car to cut off the power supply on the system and stop the car.

Alarm

:

Is a siren that can be used by the passengers stuck in the car to call for help. It continues to be supplied by the battery charge unit placed over the car even if the power supply is cut off.

Emergency Lighting

:

Automatically operates and lightens the car if power supply is cut off. It is fed by the battery charge unit placed over the car.

Interphone /Telephone systems

:

Enable the person stuck in the car to communicate with those outside the car. It continues to be supplied by the battery charge unit placed on the car even if the power supply is cut off.

Excess load system

:

Measures the load on the car and allows for the discharge of the car until the total load in the car is reduced below the acceptable capacity, in case of a load in excess of the carriage capacity.

Full load system

:

Measures the load on the car and is activated immediately below the excess load limit when even one more passenger is not allowed and provides the travel of the car responding to the internal control unit and not the external control unit until the car is adequately discharged.

Minimum load system

:

Is designed to prevent children under 12 years from using the elevator alone. It measures the weight and prevents the elevator from receiving a command from inside the car unless a minimum prerated load exists.

Rescue cover

:

Makes it possible to rescue from the top of the car the passengers stuck in the car.

Fan and natural ventilation

: Is designed to provide enough oxygen to the passengers in the car.

FIRE RESCUE SYSTEM

By communicating with the fire warning system in the building or sensing fire directly with the help of the button in the car, this system ensures that the normal control system is automatically cancelled and the elevator operates in a pre-programmed fire prevention mode.

It provides the quickest and safest evacuation of the building in case of fire.

EMERGENCY RESCUE SYSTEM

It is supplied by the uninterrupted power supply (UPS). If power is cut off during the travel, it operates automatically and ensures that the car arrives at the closest floor and the automatic door is open.

MACHINE ROOM SECURITY SYSTEMS

It enables the staff in the machine room to intervene with the elevator and the persons in the car as well as providing self-protection